Testing Items: current, voltage, power, DCIR, pulse test, capacity, cycle life, and etc.
BTS series battery test system is eight channels battery test system for Li-ion, LiFePO3, Ni-MH, Ni-CD batteries. This system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing, etc.
Battery type can be tester: pack tester for Li-ion, LiFePO4, Ni-MH, Ni-CD and lead acid battery, and etc.
Model: BTS-5V50 Material code: CT-4008W-5V50A
Power Supply AC 220V ± 10% / 50Hz or 110V
Resolution DA:16bit AD:16bit
Input Impedance ≥1MΩ
Data Sampling Frequency(Lower-subordinate ):10Hz or 100Hz
Control for Each Channel : Independent
Voltage
Voltage Range for Each Channel: Charge: 0V~5V; Discharge: 0V or 1.2V~5V
Measurement Accuracy : ±(0.1% of reading + 0.1% of range)
Stability ≤0.1%
Current
Current Range for Each Channel : Charge:100mA~50A; Discharge:100mA~50A
Accuracy :±(0.1% of reading + 0.1% of range)
Stability ≤0.1%
Power : 2000W
Time
Response time for hardware during the current range 0A to 50A≤20ms.
Step Time Range >1000 hour/step
Resolution: 1s
Accuracy :0.0001s
Data Record Condition
Time Interval Δt:(1~60000s)
Voltage Range ΔU:(5mV~5V)
Record Current Range ΔI:(50mA~50A)
Record Frequency 1Hz or 10Hz
Charge Mode
Constant current charge, Constant voltage charge, Constant current -- constant voltage,Constant power charge
INTPND Voltage, Current, Time, Capacity
Discharge Mode
Constant current discharge, Constant power Discharge , Constant resistance discharge
INTPND Voltage, Current, Time, Capacity
Cycle times: 1~9999 times
Number of Single Step 64
Watches with nested loop, supports up to 3 Nested
Safety Protection
1. Automatic backup test data on loss of utility power.
2. Upper voltage for protection can be setup; watches with off-line test.
3. Over-voltage protection, Under-voltage protection, Over-current protection, Under-current protection, Over-capability
protection; and the value can be setup.
Hardware Protection Prevent Reverse-connection Board(optional)
The Anti-interference Property on System: Anti-interference Board(optional)
Noise <85dB
Database MySQL
Host Computer Communication Based on TCP/IP Protocol
Data flow EXCEL, TXT, Graph
CI Network Port
Number of Channels for Each Unit 8
or you can visit www.newarecycler.com for more details
Charge
|
Charge Mode
|
Constant Current Charge,Constant Voltage Charge,
Constant Current and Constant Voltage Charge,CPC
|
|
End Conditon
|
Voltage,Current,Relative Time,Capacity
|
Discharge
|
Discharge Mode
|
CCD,CPD,CRD
|
|
End Condition
|
Voltage,Current,Relative Time,Capacity,
|
DCIR test supported
|
Pulse Test
|
Charge
|
CCC CCP
|
|
Discharge
|
CCC CCP
|
|
Minimum Pulse Width
|
500ms
|
|
Pulse Number
|
32 diffirent pulse for a single step
|
|
Charge And Discharge Switch
|
continuous switched for a single pulse step
|
|
End Condition
|
Voltage,Relative Time
|
Cycle
|
Loop Measure Range
|
1~65535 times
|
|
Max Steps Per Loop
|
254
|
|
Nested Loop
|
Nested loop Function,Max Support 3 Layers
|
Protection
|
Software Protection
|
- Power-down Data Protection
|
|
|
- Off-line Testing Function
|
|
|
- Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time
|
|
Hardware Protection
|
Additional Anti-reverse Protection Model
|
Voltage and Current Testing Sample
|
4-wire connecting
|
Noise
|
<85dB
|
Database
|
MySQL Database
|
A Means of Communication of Upper Machine
|
TCP/IP Protocol
|
Data Output
|
EXCEL 2003,2010,TXT
|
Communication Interface
|
Internet Access
|
Per Unit Main Channels No.
|
8
|
Rechargable Battery Pack Tester 5V50A 8 channels Features
1)According to the international standard design, each channel of the system has an independent constant-current source and a hardware constant-voltage source which make system stable & reliable
2)Modular design leads to easy maintain
3)Different holder selectable, satisfy your different needs
4)Efficient heat dissipation system, ensure proper working of equipments under 24hrs full load condition
5)Double loop-control adopted,no peak occured from CC to CV, protect the battery
****Different Specifications could be customized ,Ranging from 1mA-3000A, 5-800V;)****
If you are interested in NEWARE battery testing equipment, pls contact us !
Elley Wang Mobile:15913168930 Skype:elleywangyao