Product Description

Testing Items: current, voltage, power, DCIR, pulse test, capacity, cycle life, and etc.

BTS series battery test system is eight channels battery test system for Li-ion, LiFePO3, Ni-MH, Ni-CD batteries. This system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing, etc.

Battery type can be tester: pack tester for Li-ion, LiFePO4, Ni-MH, Ni-CD and lead acid battery, and etc.

Model: BTS-5V50                Material code: CT-4008W-5V50A
Power Supply  AC 220V ± 10% / 50Hz or 110V
Resolution DA:16bit  AD:16bit
Input Impedance  ≥1MΩ
Data Sampling Frequency(Lower-subordinate ):10Hz or 100Hz
Control for Each Channel : Independent
Voltage
Voltage Range for Each Channel:  Charge: 0V~5V; Discharge: 0V or 1.2V~5V
Measurement Accuracy : ±(0.1% of reading + 0.1% of range)
Stability  ≤0.1%
Current
Current Range for Each Channel : Charge:100mA~50A; Discharge:100mA~50A 
Accuracy :±(0.1% of reading + 0.1% of range)
Stability  ≤0.1%
Power : 2000W
Time
Response time for hardware during the current range 0A to 50A≤20ms. 
Step Time Range  >1000 hour/step
Resolution:  1s
Accuracy :0.0001s
Data  Record Condition
Time Interval Δt:(1~60000s)
Voltage Range ΔU:(5mV~5V)
Record  Current Range ΔI:(50mA~50A)
Record Frequency  1Hz  or 10Hz
Charge Mode
Constant current charge, Constant voltage charge, Constant current -- constant voltage,Constant power charge
INTPND  Voltage, Current, Time, Capacity
Discharge Mode
Constant current discharge, Constant power Discharge  , Constant resistance discharge
INTPND  Voltage, Current, Time, Capacity
Cycle  times:  1~9999 times
Number of Single Step  64
Watches with nested loop, supports up to 3 Nested
Safety   Protection
1.  Automatic backup test data on loss of utility power.
2.  Upper voltage for protection can be setup; watches with off-line test.
3.  Over-voltage protection, Under-voltage protection, Over-current protection, Under-current protection, Over-capability
protection; and the value can be setup.
Hardware Protection  Prevent Reverse-connection Board(optional)
The Anti-interference Property on System:   Anti-interference Board(optional)
Noise  <85dB
Database  MySQL
Host Computer Communication  Based on TCP/IP Protocol
Data flow  EXCEL, TXT, Graph
CI  Network Port
Number of Channels for Each Unit  8

or you can visit www.newarecycler.com for more details

Charge

Charge Mode 

Constant Current Charge,Constant Voltage Charge,

Constant Current and Constant Voltage Charge,CPC

 

End Conditon

Voltage,Current,Relative Time,Capacity

Discharge

Discharge Mode

CCD,CPD,CRD

 

End Condition

Voltage,Current,Relative Time,Capacity,

DCIR test supported

Pulse Test

Charge

CCC CCP

 

Discharge

CCC CCP

 

Minimum Pulse Width

500ms

 

Pulse Number

32 diffirent pulse for a single step

 

Charge And Discharge Switch

continuous switched for a single pulse step

 

End Condition

Voltage,Relative Time

Cycle

Loop Measure Range

1~65535 times

 

Max Steps Per Loop 

254

 

Nested Loop

Nested loop Function,Max Support 3 Layers

Protection

Software Protection

  • Power-down Data Protection

 

 

  • Off-line Testing Function

 

 

  • Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time

 

Hardware Protection

Additional Anti-reverse Protection Model

Voltage and Current Testing Sample

4-wire connecting

Noise

<85dB

Database

MySQL Database 

A Means of Communication of Upper Machine 

TCP/IP Protocol

Data Output 

EXCEL 2003,2010,TXT

Communication Interface

Internet Access

Per Unit Main Channels No.

8

Rechargable Battery Pack Tester 5V50A 8 channels Features
 
1)According to the international standard design, each channel of the system has an independent constant-current source and a hardware     constant-voltage source which make system stable & reliable

2)Modular design leads to easy maintain

3)Different holder selectable, satisfy your different needs
4)Efficient heat dissipation system, ensure proper working of equipments under 24hrs full load condition

5)Double loop-control adopted,no peak occured from CC to CV, protect the battery

 

****Different Specifications could be customized ,Ranging from 1mA-3000A, 5-800V;)****

If you are interested in NEWARE battery testing equipment, pls contact us !

Elley Wang Mobile:15913168930 Skype:elleywangyao

or you can visit www.newarecycler.com for more details

Payment Terms︰100% T/T
Product Image




Related Products
battery module cycle tester
battery module cycle tester
Coin cell battery cycle tester
Coin cell battery cycle tester
CNY ¥ 1
Coin Cell Battery Tester( 0.5A 5V 5Vper Channel)
Coin Cell Battery Tester( 0.5A 5V 5Vper Channel)
Portable Internal Resistance Tester for All Batteries 0 - 20V
Portable Internal Resistance Tester for All Batteries 0 - 20V




Home  |  Product Catalog  |  Support  |  Download  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !