USB Portable Rechargeable power pack tester 6V4A
Especially designed for USB portable power bank testing, and the testing items includes: capacity, Charge and discharge conversion efficiency test, cycle life test, OVER-VOLTAGE PROTECTIVE BOARD test, activate power function, etc.
The machine range is 6V4A, and the specs is below:
BTS-6VABattery Testing System
|
Unit Type
|
BTS-
|
6
|
V
|
4
|
A
|
Battery Testing System
|
|
Model No
|
CT-4008
|
-6V4A
|
-
|
NA
|
-
|
A1
|
Index Item
|
Index Parameter
|
Input Power
|
AC 220V ±10% / 50Hz
|
Input Active Power
|
324
|
W
|
Resolution
|
AD:16bit;DA:16bit
|
Input Resistance
|
≥1MΩ
|
Voltage
|
Per Channel Constant Voltage Control Range
|
0.03V~6V
|
Lowest Discharge Voltage
|
|
|
|
|
2.5V
|
Accurancy
|
± 0.1% of FS
|
Stability
|
± 0.1% of FS
|
Current
|
Per Channel Current Range
|
0.02A~4A
|
Accurancy
|
± 0.1% of FS
|
Constant Voltage Stop Current
|
0.008A
|
Stability
|
± 0.1% of FS
|
Power
|
Per Channel Output Power
|
24W
|
Stability
|
± 0.2% of FS
|
Time
|
Current Response Time
|
Maxmum Current ≤20ms
|
Step Time Range
|
≤h,min,s,ms)
|
Data Recording
|
Record Condition
|
Minimum Time Interval:100ms
|
Minimum Voltage Interval:12mV
|
Minimum Current Interval:8mA
|
Record Frequency
|
10Hz
|
Charge
|
Charge Mode
|
Constant Current Charge,Constant Voltage Charge,Constant Curren and Voltage Charge,Constant Power Charge
|
End Condition
|
Voltage,Current,Relative Time,Capacity
|
Discharge
|
Discharge Mode
|
CCD,CPD,CRD
|
End Condition
|
Voltage,Current,Relative Time,Capacity,Voltage Interval
|
Pulse Test
|
Charge
|
CCC CCP
|
Discharge
|
CCC CCP
|
Minimum Pulse Width
|
500ms
|
Pulse number
|
32 diffirent pulse for a single step
|
Charge and Discharge Constant Switch
|
Support continuous switched in a single pulse step
|
End Condition
|
Voltage,Relative Time
|
DCIR Test
|
Support
|
Cycle
|
Loop Measure Range
|
1~65535 times
|
Max Steps Per Loop
|
254
|
Nested Loop
|
Nested loop Function,Max Support 3 Layers
|
Protection
|
Software Protection
|
● Power-down Data Protection
|
● Off-line Testing Function
|
● Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time
|
Hardware Protection
|
Additional Anti-reverse Protection Model
|
Channel Control
|
Independent control per channel
|
Voltage and Current Testing Sample
|
4-wire connecting
|
Noise
|
<85dB
|
Database
|
MySQL
|
Upper Machine Cummunication mode
|
Based on TCP/IP
|
Data Output
|
EXCEL2003,2010,TXT
|
Server disk configuration
|
500GB
|
Leak Current
|
0.006mA
|
Server Operating System
|
Windows XP,Windows 7
|
Communication Interface
|
Internet Access
|
Equipment Working Environment
|
Index Item
|
Index Parameter
|
Working Temperature Range
|
0℃~40℃
|
Storage Temperature Range
|
-10℃~50℃
|
Working Environment Relative Humidity Range
|
≤70% RH
|
Storage Environment Relative Humidity Range
|
≤80% RH
|
****Different Specifications could be customized ,Ranging from 1mA-3000A, 5-800V;)****
If you are interested in NEWARE battery testing equipment, pls contact us !
Elley Wang Mobile:15913168930 Skype:elleywangyao Email: elley.wangyao@gmail.com / wangyao@neware.com.cn